5.Periodic Inspection/Maintenance

5-10

5.5.9 Clean of element in sedimenter

[Every 500 hours]

<Procedure>

①

Turn fuel selector valve“1”to“OFF”position.

②

Loosen the drain valve“2”and drain out condensed

water inside.

③

Turn the cup“3”to the left and remove it.

Be careful to remove the cup“3”because it is filled
with fuel. Wipe out split fuel completely.

④

Remove float“4”inside cup“3”.

⑤

Washing element“5”and the cup inside with new

fuel.

⑥

Replace element“5”and o-ring“6”,“7”if they are

found broken or damaged. (For part number, see 5.4)

⑦

After finishing clean, assemble it in reverse

procedure.



If air is found still in fuel pipe, place starter switch

to“RUN”position and loosen air bleeding bolt“8”
to bleed air. After finishing air bleeding, tighten the
air bleeding bolt“8”.



Drain the condensate in container“9”,and then

dispose of condensate according to the designated
regulations.

5.5.10 Change fuel filter

[Every 500 hours]

<Procedure>

①

Remove the fuel filter cartridge“1”, using a filter wrench.

②

Install the new cartridge“1”after applying oil to the

surface of gasket“2”of cartridge“1”.
(For part number, see 5.4)

③

Give 1 turn to the cartridge“1”by hand after the packing

touches the sealing face.

④

After installing fuel filter cartridge“1”, check for fuel leak

during operation.


A100117

1 8

7
6

5

3

4

2

9

ON

OFF

H000049

1

2