5.Periodic Inspection/Maintenance

5-13

A100370-1

<Procedure>

①

To drain coolant, remove the radiator cap“1”Remove out side radiator drain plug “2” and open

drain valve“3”for drainage.

②

Loosen the drain plug“4”provided on engine to drain engine.

③

After drainage is finished, tighten drain plug“2”,“4”and then close radiator drain valve “3”.

[Quantity of water:approx. 1.5 gal.(5.8L)]

④

After changing the coolant, operate the machine for 2 to 3 minutes at the unloaded condition and
stop it. Then check the coolant level again, and replenish if it is short.

5.5.17 Change nylon tubes

[2,000 hours or every 2 years]



Replace nylon tubes used for the oil and air pipings.



When replacing it, contact directly us or distributor because it requires expert technical
knowledge.




5.5.18 Change fuel hose

[2,000 hours or every 2 years]



In case various rubber hoses for fuel system and engine lubrication system are hardened or
deteriorated, replace them even before the specified replacement time.



When replacing hoses, contact directly us or distributor because it requires expert technical
knowledge.