Installing the fireplace, Introduction, Cautions – Montigo E36DV-RV User Manual

Page 2: Selecting your fireplace location, Figure 1. fireplace dimensions, Figure 2. framing dimensions

Advertising
background image

Page 2 of 11

0 9 / 9 6

INSTALLING THE FIREPLACE

The Econo Plus 36DV-RV clearances to combustible materials are
0" back, 1" sides, 0" floor and 4" top. The Econo Plus 36DV-RV must
not be installed any closer than 8 inches to any unprotected
combustible wall perpendicular to the fireplace opening.

For protection against freezing temperatures, it is recommended that
the outer walls of the chase be insulated with a vapour barrier. This
will reduce the possibility of a cold-air convection current on the
fireplace.

THE FRAMING DIMENSIONS ARE SHOWN BELOW:

INTRODUCTION

The Econo Plus 36DV-RV is rated at 16,000 BTUs. (4.16 Kilowatts)
for Natural & Propane gas.
The Econo Plus warranty will be voided by, and Econo Plus
disclaims any responsibility for, the following actions:

- Modification of the fireplace and/or components including

Direct-Vent assembly or glass doors.

- Use of any component part not manufactured or approved by

Econo Plus in combination with a Econo Plus fireplace system.

- Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch about the particular
requirements concerning installation of factory-built gas fireplaces.
Installation & repairs should be done by a qualified contractor,
and installation must conform with the current CAN/CGA
B-149.1 and .2 Gas Installation Code and local regulations.

CAUTIONS

* Due to its high operating temperatures, the appliance should be

located out of traffic & away from furniture and draperies.

* Children and adults should be alerted to the hazards of the high

surface temperature, which could cause burns or clothing ignition.

* Young children should be carefully supervised when they are in

the same room as the appliance.

* Clothing or other flammable materials should not be placed on

or near the appliance.

SELECTING YOUR FIREPLACE LOCATION

The fireplace may be installed in any location that is free of air
condition ducts, electrical wiring and plumbing. Safety, as well as
efficiency of operation, must be considered when selecting the
fireplace location. Try to select a location that does not interfere
with room traffic, has adequate ventilation, and offers an accessible
pathway for Direct Vent & Combustion Air Kit installation.

The fireplace dimensions are shown below:
NOTE: SEE FIGURE 2 FOR FRAMING DIMENSIONS

FIGURE 1. FIREPLACE DIMENSIONS

19

16 1/4

10 1/4

37 1/2

3 3

39 1/2

17

36

25 1/2

12

12

37 1/2

12

12

36

25 1/2

17

37 1/2

FIGURE 2. FRAMING DIMENSIONS

37 1/2

59

16 1/4

19

12

42

Advertising
This manual is related to the following products: