This appliance may be installed as an OEM installa-

tion in a manufactured home (USA only) or mobile

home and must be installed in accordance with the

manufacturer's instructions and the Manufactured

Home Construction and Safety Standard, Title 24 CFR,

Part 3280, in the United States or The Mobile Home

Standard, CAN / CSA Z240 MH Series, in Canada. This

appliance is only for use with the type(s) of gas indi-

cated on the rating plate. A conversion kit is supplied

with the appliance.

Gas Control Valve

The following gas control valve is installed on the M40DV-CR/CL-MH.

Figure B1. Sit Nova 820 gas valve.

Manifold Pressure

Test Connection

Pilot Adjustment Screw

Inlet

Pressure

Power

Generator

Wall Switch

M40DV-CR/CL-MH Mobile Home

The mobile home option is a factory installed on the M40DV-CR/CL-
MH gas fireplace, and is for use in a manufactured or mobile home.

The standard M40DV-CR/CL or the M40DV-CR/CL-I equipped with

Hot Surface Ignition (HSI) are not approved for use in mobile or

manufactured homes.
The M40DV-CR/CL-MH is rated for:

Natural Gas at 30,000 BTU/H (8.79 Kilowatts) max. input, and

24,000 BTU/H (7.03 Kilowatts) min. input.

Propane at 30,000 BTU/H (8.79 Kilowatts) max. input, and

24,000 BTU/H (7.03 Kilowatts) min. input.

Conversion Kits

The M40DV-CR/CL-MH mobile home appliance is field convertible
between Natural Gas (NG) and Propane (LP).
To convert from Natural Gas to Propane order conversion kit #
RCV725.
To convert from Propane to Natural Gas order conversion kit #
RCV825.
Conversion kits are available for standard M40DV-CR/CL conversion
between Natural Gas (NG) and Propane (LP).

A manufactured home (USA only) or mobile home

OEM installation must conform with the Manufactured

Home Construction and Safety Standard, Title 24 CFR,

Part 3280, or when such a standard is not applicable,

the Standard for Fire Safety Criteria for Manufactured

Home Installation Sites and Communities, ANSI/NFPA

501A, in the United States or the Mobile Home Stand-

ard, CAN / CSA Z240 MH Series, in Canada.