595-5631-07

Controlling Non-Motion Sensing Fixtures

When wiring to additional standard fixture

only: Strip the motion sensor's red wire and
connect to the standard light's black wire. Con-
nect all white wires together. Total fixture
ratings must not exceed 1000W (8.3 A).

NOTE: All wiring between fixtures should be run

in accordance with the National Electrical Code
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.

This fixture is provided with a sensor rated

for 1000W. Since the fixture is only rated 300W,
700W of additional load may be controlled by
this sensor.

When determining what a fixture is rated for,

do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.

Once you have selected the fixtures to be con-

nected and determined their maximum ratings,
add these ratings up. For instance, if you have
3 fixtures rated 100W, 150W, and 75W respec-
tively, you have a total load of 325W.

(Standard)

RED from

JourneyMan

®

to BLACK

from Fixture

BLACK from

Switch to

BLACK from

JourneyMan

®

WHITE from

Line to

WHITE from

JourneyMan

®

WHITE from

Line to WHITE

from Fixture

Wiring to a Motion Light & Standard Fixture