Storage, Maintenance, Specifications – Desa 30LP User Manual

Page 6

Advertising
background image

6

104163

PROPANE CONSTRUCTION HEATER

30,000 BTU/Hr

STORAGE

1.

Store propane tank(s) in safe manner.
See Chapter 5 of Standard for Storage
and Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58.
Follow all lo-
cal codes. Always store propane tanks
outdoors.

2.

Place plastic cover caps over brass
fittings on inlet connector and hose/
regulator assembly.

3.

Store in dry, clean, and safe place. Do
not store hose/regulator assembly in-
side heater combustion chamber.

4.

When taking heater out of storage, al-
ways check inside of heater. Insects and
small animals may place foreign ob-
jects in heater. Remove motor and other
internal parts if needed to remove for-
eign objects (see Service Procedures,
page 8).

MAINTENANCE

CAUTION: Disconnect heater

from propane supply tank(s).

WARNINGS

• Never service heater while it is

plugged in, connected to pro-
pane supply, operating, or hot.
Severe burns and electrical
shock can occur.

• Keep heater clear and free from

combustible materials, gaso-
line, and other flammable va-
pors and liquids.

• Do not block the flow of com-

bustion or ventilation air.

1.

Keep heater clean. Clean heater annu-
ally or as needed to remove dust and
debris. If heater is dirty or dusty, clean
heater with a damp cloth. Use house-
hold cleaners on difficult spots.

2.

Inspect heater before each use. Check
connections for leaks. Apply mixture
of liquid soap and water to connections.
Bubbles forming show a leak. Correct
all leaks at once.

3.

Inspect hose/regulator assembly be-
fore each use. If hose is highly worn
or cut, replace with hose specified by
manufacturer.

SPECIFICATIONS

Output Rating (BTU/Hr)

30,000

Fuel

Propane Vapor Only

Fuel Consumption

Gallons/Hour

.33

Pounds/Hour

1.4

Supply Pressure To Regulator

Minimum (for purposes

20 psi

of input adjustment)
Maximum

Tank Pressure or 200 psi

Regulator Outlet Pressure

10 PSI

Manifold Pressure

10.1 PSI

Hot Air Output
(CFM Approx)

175

Motor

3045 RPM

Electric Input

120 volt/60 hertz

Amperage

.6

Ignition

Manual, Piezo

Weight (Pounds)

Heater

9

Shipping

9.5

Size - L x W x H (Inches)

Heater

18.5 x 7.7 x 12.8

Temperature Range for Heater Operation

-20

°

F to 85

°

F*

* When running heater in temperatures above 85

°

F, high internal temperatures may cause

thermal limit device to shut down heater.

4.

Have heater inspected yearly by a quali-
fied service agency.

5.

Keep inside of heater free from com-
bustible and foreign objects. Remove
motor and other internal parts if needed
to clean inside of heater (see Service
Procedures,
page 8).

6.

Clean fan blades each season or as
needed (see Fan, page 9).

Advertising