5.2 Front panel

– Status monitoring

The status of the module can be easily monitored visually by the LED’s at the front of the
module. The LEDs are visible through the front panel as shown in the figure below.

The 3GHD-EO(-2)

has 4 LED’s each showing a status corresponding to the GPI pinning.

Diode \ State

Red LED

Yellow LED

Green LED

No light

Status

Module is faulty, or
module is initializing.

N/A

Module is OK
Module power
is OK

Module
has no
power

LOS/LOCK1 No input signal on

optical output 1.

Input signal on
optical output 1
but reclocker not
in lock.

Input signal on
optical output 1
and reclocker in
lock.

LOS/LOCK2 No input signal on

optical output 2.

Input signal on
optical output 1
but reclocker not
in lock.

Input signal on
optical output 1
and reclocker in
lock.

Laser fail

Laser is
malfunctioning.

Laser is off

Laser is OK