4.2.2 Multicon Gyda configuration

The Flashlink Compact does not store configuration set from Multicon

Gyda.

This means that the Flashlink Compact will after a power recycling receive stored
parameters from Multicon Gyda.

4.2.2.1 Card label

Assigns a name. When the locate is pushed all indicators on front of the Flashlink
Compact will flash for 120 seconds, alternative an period can be enter into the sec box.

4.2.2.2 Firmware upgrade

Updates the firmware on Flashlink Compact. The firmware file first has to be uploaded
to Multicon Gyda by ftp. See user manual on Multicon Gyda for help on uploading.

4.2.2.3 Electrical input

For SDI signal set the electrical input to normal. For MADI and other low bitrate none
SDI signal set this to EQ bypass.

The alarm handling for the electrical input can be turn on or off by the normal and
ignore radio button. Also the SNMP alarm trap can be turn on or off by send or ignore
radio button.

4.2.2.4 Electrical output

Turns on and off the output signal. When in auto mode the state of reclocker controls
the output state. If reclocker is in lock then output is on, else output is off. If reclocker is
in bypass the output is on.

4.2.2.5 Reclocker

For SDI signal set to enable, else set to bypass. Autobypass only works if the reclocker
is enabled. With autobypass on the reclocker will set the reclocker in bypass mode
when none SDI signal is detected.

The alarm handling for the reclocker can be turn on or off by the normal and ignore
radio button. Also the SNMP alarm trap can be turn on or off by send or ignore radio
button.

4.2.2.6 Optical input
No configurable parameters.