2 front panel, Status monitoring, 2 front panel – status monitoring – Nevion LB-EO Rev.F User Manual

Page 12

Advertising
background image

LB-EO

Rev. F


nevion.com | 12

5.2 Front panel

– Status monitoring

The status of the module can be easily monitored visually by the LED’s at the front of the
module. The LED’s are visible through the front panel as shown in the figure below.

Figure 5: Front panel indicators for the LB-EO.

The LB-

EO has 4 LED’s each showing a status showed in the table below.

Diode / State

Red LED

Green LED

Orange LED

No light

STATUS

Module is faulty,
or module is
initialising.

Module is OK
Module power is
OK

Module has
no power

LOS

No signal

Signal is present

Module has
no power

LEVEL

Signal level too
high

– increase

attenuation or
reduce input level

Signal level
critical - increase
attenuation or
reduce input level

Signal level
not critical

LASER FAIL

Laser failure

Laser OK

Module has
no power