DIP switch configuration must be set according to the table below:
Switch
#
Label
Function,
DIP = ON
Function,
DIP = OFF
Comment
1
AGC
Automatic gain
control
Manual gain control
2
R/S
Run AGC
Sample AGC level
Only valid in Manual gain
control
3
LNB
Enable power
supply for LNB
Disable power
supply for LNB
4
H/V
Horizontal
polarization
Vertical polarization Sets voltage on LNB
5
LLC
Line length
compensation on
Line length
compensation off
If on, output voltage from card
to LNB will increase by 1 volt.
Set to ON when using long
cables (cable more than
approx 3 ohms DC resistance
in cable)
6
H/L
High band
Low band
22kHz tone control
7
GPI
H/V and H/L
controlled by GPI
H/V and H/L
controlled by DIP
or GYDA
When GPI is set, DIP 4 and 6
will be disregarded
8
OVR
Override GYDA
control. Config.
with DIP switch
GYDA control.
Config. with GYDA
Select configuration from
GYDA
All DIP switches are off when pointing towards the release handle.