Nevion LB-EO Rev.F User Manual

Page 8

Advertising
background image

LB-EO

Rev. F


nevion.com | 8

DIP switch configuration must be set according to the table below:

Switch

#

Label

Function,

DIP = ON

Function,

DIP = OFF

Comment

1

AGC

Automatic gain
control

Manual gain control

2

R/S

Run AGC

Sample AGC level

Only valid in Manual gain
control

3

LNB

Enable power
supply for LNB

Disable power
supply for LNB

4

H/V

Horizontal
polarization

Vertical polarization Sets voltage on LNB

5

LLC

Line length
compensation on

Line length
compensation off

If on, output voltage from card
to LNB will increase by 1 volt.
Set to ON when using long
cables (cable more than
approx 3 ohms DC resistance
in cable)

6

H/L

High band

Low band

22kHz tone control

7

GPI

H/V and H/L
controlled by GPI

H/V and H/L
controlled by DIP
or GYDA

When GPI is set, DIP 4 and 6
will be disregarded

8

OVR

Override GYDA
control. Config.
with DIP switch

GYDA control.
Config. with GYDA

Select configuration from
GYDA

All DIP switches are off when pointing towards the release handle.