5 module status, 1 front panel, Status monitoring – Nevion 10G-TR-C1xxx User Manual

Page 8: 5module status, 1 front panel – status monitoring

Advertising
background image

10G-TR-C1xxx

Rev. B


nevion.com | 8

5

Module status

The status of the module can be monitored in two ways.

1. Multicon GYDA System Controller (optional).

2.

LED’s at the front of the sub-rack.

T

he LED’s are mounted on the module itself, whereas the GYDA System Controller is

a separate module giving detailed information on the card status.

5.1 Front panel

– Status monitoring

The status of the module can be easily monitored visually by the LED’s at the front of
the module. The LEDs are visible through the front panel as shown in the figure below.

Figure 5: The 10G-TR has 3

LED’s each showing a status.

Diode \ State

Red LED

Yellow LED

Green LED

No light

Status

Module is faulty, or
module is initializing.

N/A

Module is OK
Module power
is OK

Module
has no
power

LOS/LOCK1

No input signal on
input

Channel is not in
lock or
unsupported
format.

Channel is in
lock and
supported
format.

N/A

LASER FAIL

Laser is faulty or
turned off by DIP or
control system

N/A

Laser is turned
on

N/A

Table 1: LED states and what they mean