3 front panel, Status monitoring, 3 front panel – status monitoring – Nevion DVI-SDI-2-SFP User Manual

Page 11

Advertising
background image

DVI-SDI-2-SFP

Rev. C


nevion.com | 11

6.3 Front panel

– Status monitoring

The status of the module can be easily monitored visually by the LED’s at the front of the
module. The LEDs are visible through the front panel as shown in the figure below.

The DVI-SDI-2

has 4 LED’s each showing a status corresponding to the GPI pinning.

Diode \ State Red LED

Yellow LED

Green LED

No light

Status

Module is faulty, or
module is initializing.

N/A

Module is OK

Module power
is OK

Module
has no
power

LOS/LOCK1 No input signal on

input 1.

Channel 1 is not
in lock or
unsupported
format.

Channel 1 is in
lock and
supported
format.

Missing
SFP on
signal 1

LOS/LOCK2 No input signal on

input 2.

Channel 2 is not
in lock or
unsupported
format.

Channel 1 is in
lock and
supported
format.

Missing
SFP on
signal 1

Transmitter
SFP

Missing SFP

NA

Present SFP

NA

Table 1: LED states and what they mean