DA-3GHD-2x4
Rev. C
nevion.com | 12
GPI name
(setup1/
setup2)
Function
(setup1/ setup2)
Pin #
Mode
Direction
Electrical
Maximums
for GPI
outputs:
Max current:
100mA
Max voltage:
30V
Max power:
200mW
Status
General error status for the
module.
Pin 1
Inverted Open
Collector
(open is alarm)
Output
Not used
Pin 2
Signal
present 1
Good signal routed to
output 1
Pin 3
Inverted Open
Collector
(open is alarm)
Output
Signal
present 2
Good signal routed to
output 2
Pin 4
Inverted Open
Collector
(open is alarm)
Output
Not used
Pin 5
Not used
Pin 6
Not used
Pin 7
Ground
0 volt pin
Pin 8
0V.
Table 4: Description of GPI interface