Multicon SNMP Data Model

Rev. 0

nevion.com | 9

3 Notifications

Multicon has the capability to send SNMP notifications (traps) when alarms occur in a
Flashlink system or VikinX router. The trap types supported are listed in the MIB file.
There are one trap type indicating the raise of an alarm and a corresponding trap type to

indicate clear of an alarm. Each trap type contains values from the SNMP data model
pertaining to the alarm situation, which enables SNMP managers to poll for more

information when a trap is received.
Example:
nworkLossOfOptSignal TRAP-TYPE

ENTERPRISE generic
VARIABLES { busSysType, busNum, moduleNum, moduleLabel, optInputNum }

DESCRIPTION "Loss of input signal on optical input."

::= 3

nworkCorrectOptSignal TRAP-TYPE

ENTERPRISE generic

VARIABLES { busSysType, busNum, moduleNum, moduleLabel, optInputNum }
DESCRIPTION "Signal on optical input comes back after having been lost."

::= 4

The example above shows an loss of optical signal alarm and a corresponding clear alarm. In

each case the values of busSysType, busNum, moduleNum, moduleLabel and optInputNum

is sent with the trap.