Upon receipt of the UPS, inspect the shipping carton for damage. If there is
any obvious damage, immediately report it to the selling dealer or the
delivering carrier. If there is no damage to the shipping carton, unpack the
unit and inspect the unit for damage.

The UPS is designed for installation in a protected environment within a
temperature range from 32°F to 104°F and relative humidity of 0

90%

without condensation. Do not block inlets and outlets. Install the system in a
location free from excessive dust and chemical fumes.

Check the identification label to verify the UPS voltage and power rating
match the available line voltage and load requirements.

Installation:

1. Check if the main switch on the UPS front panel is in the off position and

insure that the voltage of the AC utility source corresponds to the
nameplate on the UPS rear panel.

2. Plug the power cable into the grounded socket.
3. Push the main switch, then the Load Level LCD(

) will light on after 2

seconds and CUT-OFF LCD(

) will light off. The UPS will then get

ready and start to work normally.

4. Connect your PC with UPS, then turn on PC. Be sure to check the

Load Level LCD(

) indicator and DO NOT

OVERLOAD it over 100%. To simulate AC failure (Push UPS test
switch) can help to insure whether UPS is in good condition or not. It is

designed to alarm every 3 seconds and with BACK-UP LCD(

-

) light

on when simulation starts. If the CUT-OFF LCD(

) is on, it means

UPS fault or BATTERY fault. Then you have to contact your local
service center

5. When battery approaches low level(

-

),

alarm will beep every second until auto shut down

6. The 4 conditions UPS will automatically shut down:

a. Battery low
b. Short circuit
c. Overload
d. UPS fault

- 7 -