3 environmental specifications, 5 unit nomenclature – Northern Airborne Technology RS16 User Manual

Page 8

Advertising
background image

RS16 Series Remote Switch Manual

SM15 Rev. 4.00

Page 1-2

Nov 24, 2003

ENG-FORM: 800-0106.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

1.4.3 Environmental

Specifications

Operating Temperature

-40

°C to +70°C

Altitude

35,000 ft. max.

Humidity

95 % Non-Condensing

Shock

12 g. (any axis)

1.5 Unit

Nomenclature

NOTE: The RS128 and RS192 families are derivative products that simply contain
multiple RS16 cards in a single enclosure. All performance characteristics and test
procedures are the same as those for the RS16.

Model

Description / Distinction

RS16-001

16P2T data switch, GREEN annunciation. Can be mapped for voltage or
ground keying. ILS reversion relay.

RS16-101 16P2T data switch, card only (does NOT include enclosure), GREEN

annunciation. Can be mapped for voltage or ground keying. ILS reversion relay.

RS16-102

16P2T data switch, card only (does NOT include enclosure), RED annunciation.
Can be mapped for voltage or ground keying. ILS reversion relay.

RS128-000 Empty enclosure, allocated space for 8 RS16 cards. User may choose

combinations of RS16 cards.

RS128-008 Pre-filled with 8 RS16-101 cards for 128P2T operation.

Each RS16 card has an ILS reversion relay.

RS128-999 Pre-filled with 8 RS16-101 cards. Each RS16 card is hard-wire jumpered

to the normally closed position for each of the 16 contacts (relays
removed). Used to permit flight with the RS128-008 removed.

RS192-000 Empty enclosure, allocated space for 12 RS16 cards. User may choose

combinations of RS16 cards.

RS192-012 Pre-filled with 12 RS16-101 cards for 192P2T operation.

Each RS16 card has an ILS reversion relay.

RS192-999 Pre-filled with 12 RS16-101 cards. Each RS16 card is hard-wire jumpered

to the normally closed position for each of the 16 contacts (relays
removed). Used to permit flight with the RS192-008 removed.


End of section 1.0