Grounding recommendation – OpenEye CM-511 Installation Manua User Manual
Page 24
Advertising

24
Grounding Recommendation
The GND (ground) wire must be directly connected to the middle pin of the AC24V power connector. Failure to
connect the ground can cause damage and failure of the camera and may void the warranty.
If the connection of the GND wire causes video noise, use a video isolator. This is only necessary in some
situations.
AC 24V
VIDEO OUT
Must be
connected
to ground
(GND)
Video
Isolator
Optional
AC 24V•
Adapter
3 pins terminal block
VIDEO OUT
RS-485
Alarm I/O
2
3
4