OPERATING FIREPLACE

Operating Optional GWMT1 Wall Mounted Thermostat

Operating Optional Blower Accessory

INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

OPERATING FIREPLACE

Continued

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower louver panel on
the fireplace. Blower controls are located on the left side of the
switch bracket to the left just inside the louver panel.

The BK manual blower and the BKT thermostatically-con-
trolled blower have an ON setting and an OFF setting. The
blower will only run when the switch is in the ON position. In the
OFF position, the blower will not operate.

Note for BKT Only:

If you are using BKT blower with optional

thermostat (wall mounted or remote control) for the fireplace,
your fireplace and blower will not turn on and off at the same
time. The fireplace may run for several minutes before the
blower turns on. After the heater modulates to the pilot position,
the blower will continue to run. The blower will shut off after the
firebox temperature decreases.

The blower helps distribute heated air from the fireplace.
Periodically check the louvers of the firebox and remove any
dust, dirt, or other obstructions that will hinder the flow of air.

OPERATING OPTIONAL GWMT1

WALL MOUNTED THERMOSTAT

Light the fireplace as instructed in Lighting Instructions on page
25. Set wall thermostat to desired temperature.

This thermostat has been electronically calibrated at the factory
and requires no adjustment or leveling.

Upon installation, the thermostat must be allowed to stabilize at
room temperature for a minimum of 30 minutes for proper
operation.

To turn the fireplace off, adjust thermostat to the lowest setting
and turn the gas control knob back to PILOT. The pilot will
remain lit.

IMPORTANT:

To turn the pilot off, turn the gas control knob

on the heater to the OFF position.

WARNING: Do not connect the thermostat to a

power source. Electrical shock and/or a fire hazard
will occur.

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height.
Alterations may have occurred during shipping and handling. Call
a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot
flame as shown in Figure 55. The thermocouple must be at a height
of about 1/8" above the pilot flame. The flame from the pilot burner
must extend beyond both the thermocouple and thermopile.

If you pilot assembly does not meet these requirements:

• turn fireplace off (see To Turn Off Gas to Appliance, page 25)

• see Troubleshooting, pages 29 through 31

INSPECTING BURNERS

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns
will be different from unit to unit and will vary depending on
installation type and weather conditions.

If the vent configuration is installed incorrectly, the flames will lift
or "ghost". This can be dangerous. Inspect the flames after installa-
tion to ensure proper installation and performance.

Figure 56 shows a typical flame pattern for (V)T32 and (V)T36 series
models.

If burner flame pattern differs from that described:

• turn fireplace off (see To Turn Off Gas to Appliance, page 25)

• see Troubleshooting, pages 29 through 31

Figure 55 - Typical Flame Pattern for (V)T32 and (V)T36 Series
Models

Thermocouple

Thermopile

1/8"

Pilot Burner

Piezo
Ignitor

Figure 54 - Pilot Assembly

3/8" to 1/2"