Fireplace Installation and Operation Manual

_____________________________________________________________________ 45

See Appendixes for fresh air intake kit (L) and forced air distributionkit (K) installation.

Fresh air intake kit and forced air distribution kit installation

LEGEND

Combustible material allowed in

this area

Non-combustible material only in

this area

MINIMUM MEASUREMENTS

FOR FRESH AIR INTAKE KIT**

MINIMUM MEASUREMENTS

FOR FORCED AIR DISTRIBUTION

KIT**

J*

12" (305 mm)

18" (457 mm)

H*

12" (305 mm)

18" (457 mm)

*When drywall panels or any other finishing material inside the chase around the fireplace is to be
used, add its thickness to the measurement.

** The fresh air intake kit and the forced air distribution kit may be installed either on the sides or
on the back.