5.Advanced User Guidebook

24

How to Set the Vertical System

The VERTICAL CONTROLS includes 5 menu buttons such as CH1 CH4
and Math, and 8 knobs such as VERTICAL POSITION, VOLTS/DIV for each
channel.

Setting of CH1 CH4

Each channel has an independent vertical menu and each item is set respectively
based on the channel.

To turn waveforms on or off (channel, math)

Pressing the CH1 CH4 or Math buttons have the following effect:

• If the waveform is off, the waveform is turned on and its menu is displayed.

• If the waveform is on and its menu is not displayed, its menu will be displayed.

• If the waveform is on and its menu is displayed, the waveform is turned off and

its menu goes away.

The description of the Channel Menu is shown as the following list:

Function Menu Setting Description

Coupling

DC
AC
Ground

Pass both AC and DC components of the input signal.
Block the DC component of the input signal.
Disconnect the input signal.

Impedance

1MΩ
50

Ω

Select the input impedance to use. When 50

Ω is

selected, AC in coupling is not available. If the
impedance is set to 50

Ω when using AC coupling, the

coupling will be set to DC automatically.

Inverted

ON
OFF

Display inverted waveform.
Display original waveform.

Probe

X1
X10
X100
X1000

Match this to the probe attenuation factor to have an
accurate reading of vertical scale.

Limit

Full
20M

Get full bandwidth.
Limit the channel bandwidth to 20MHz to reduce
display noise.

1. To set channel coupling

Taking the Channel 1 for example, the measured signal is a square wave
signal containing the direct current bias. The operation steps are shown as