10. Press the UP arrow temperature adjustment button

several times to increase the temperature to a maximum

of 185*, see Figure 4. This will verify the unit has been

successfully converted. If the temperature does not

increase past 120 or 140, then the conversion failed,

disconnect and restore power and restart the procedure at

step 5.

11. Set the remote control to the desired operating

temperature, and restore the gas and water service to the

water heater.

12. Place/Stick Conversion Label to the front of the tankless

water heater and remove the Energy Star label. Leave the

new warranty certificate for the customer and discard the

original warranty certificate.

Available Thermostat Settings - Factory Configuration

F

85

100 102 104 106 108 110 112 114 116

118

120

C

29

38

39

40

41

42

43

44

46

47

48

49

Residential High

Temperature

Settings

Commercial High

Temperature Settings

F 125 130 135 140

F

150 160 170 180* 185*

C

52

54

57

60

C

66

71

77

82*

85*

With this Commercial Conversion the temperature ranges

available through the thermostat control are as follows:

* Some models may be able to reach up to 180°F (82°C)

!

DANGER: Hotter water increases the potential for Hot

Water SCALDS.

Commercial Conversion in a Multi-Unit Manifold

or EZ-Link™ Installation

Commercial Conversion of water heaters in a Multi-Unit

Manifold or EZ-Link™ Installation requires that each

tankless water heater in the installation gets a conversion chip

installed on the Control Board, as in steps 1 through 4. After

the chip installation the Program Chip Initiation is slightly

different from a single unit conversion since in a Multi-

Unit installation there is only one remote control. Complete

the entire manifold installation before continuing with the

Commercial Conversion procedure.
A. Complete the chip installation on each water heater as in

steps 1 through 4 on the front side of this document.

B. Find the two DIP switches located at the top right hand

side of the PCB. The switch labeled “DIP1” in the top

switch.

C. Change the DIP Switch #4 setting to the “ON” position.

DO NOT alter any other DIP Switch. The LED on the

PCB is flashing. At the same time, the display of the

Main Remote Control starts to flash.

D. Press the “Max” button located at the top right hand side

of the PCB for more than 1 second. The LED on the PCB

starts illuminating continuously. At the same time, the

display of the Main Remote Control is on continuously.

E. Change the DIP Switch #4 setting back to the “OFF”

position. DO NOT alter any other DIP Switch. The LED

on the PCB will stop illuminating. At the same time, the

display of the Main Remote Control will turn off.

F. Turn on the water heater at the remote control by pressing

the power button, see figure 3.

G. Press the UP arrow temperature adjustment button

several times to increase the temperature to a maximum

of 185*, see figure 4. This will verify the system has

been successfully converted. If the temperature does

not increase past 120 or 140, then the conversion failed,

restart the procedure at step A.

H. Set the remote control to the desired operating

temperature, and restore the gas and water service to the

manifold system.

I. Place/Stick Conversion Label to the front of the tankless

water heater and remove the Energy Star label. Leave the

new warranty certificate for the customer and discard the

original warranty certificate.