Air systems – Paslode PF350S PowerFramer 30 Framing Nailer User Manual

Page 7

Advertising
background image

7

AIR SYSTEMS

For air-powered tools to work their best, the air

supply system must be properly installed and

maintained regularly. A drawing in this section

shows a properly installed air supply system.

Handy checklists for installing and maintaining

air supply systems follow.

Indoor Air System Installation

-Be certain that:

s

All pipes supplying air have a large enough

inside diameter to ensure adequate air supply.

s

The main supply pipe slopes down, away from

the compressor (1/16 inch per foot).

s

Air storage is provided along lengthy air lines.

s

Pipe line branch outlets are at the top of the

main pipe line.

s

Cutoff valves are provided at each branch pipe

line throughout the system.

s

Water legs extend from the bottom of each branch

line.

s

A refrigerant-type dryer is installed on the system.

s

Air hoses are kept as short as practical.

s

A regular maintenance program is followed.

Outdoor Air System Installation

-Be certain that:

s

A moisture trap and a filter/regulator/lubricator are

installed at the compressor.

s

Air hoses and fittings are large enough so that air

flow is not restricted. Minimum hose size is 3/8

inch ID with 1/2 inch ID hose used for any

application over 25 feet.

s

Air hoses are not longer than 150

feet.

s

The air system is lubricated regularly.

s

A regular maintenance program is followed.

Filter/Regulator/Lubricator Units

Filter/regulator/lubricator units that can supply
enough air and protection for Paslode tools
must meet the following specifications:

s

Minimum 3/8 inch NPT port size .

s

50 micron or fine filters.

s

Regulated pressure from zero to 120 psi.

s

Lubricators designed for low or changing

airflow.

Advertising