Operating heater, Continued – Desa CGD3018N User Manual

Page 18

Advertising
background image

107123-01F

For more information, visit www.desatech.com

For more information, visit www.desatech.com

18

OPERATING HEATER (MANUALLY CONTROLLED MODELS)

Lighting Instructions (Cont.)
Variable Control Operation
To Turn Off Gas To Appliance
Manual Lighting Procedure

OPERATING HEATER (THERMOSTATICALLY-CONTROLLED MODELS)

For Your Safety Read Before Lighting

OPERATING HEATER

Continued

WARNING: Do not operate heater between PILOT

and HIGH positions.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Lighting Instructions, page 17.

2.

Depress control knob and light pilot with match.

3.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
step 8, column 1.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Press in and turn control knob clockwise

Clockwise

to the

HI position.

2.

Turn control knob clockwise

Clockwise

to the pilot position.

3.

Press in control knob and turn clockwise

Clockwise

to the

OFF position.

Shutting Off Burner(s) Only (pilot stays lit)

1.

Turn control knob clockwise

Clockwise

to the HI position.

2.

Press in and turn control knob clockwise

Clockwise

to the

pilot position.

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

The variable control valve can be set to any heat setting and
flame height desired, by simply turning the control knob until
that setting is attained. Even the lowest setting provides realis-
tic, dancing yellow flames. Selecting higher settings produces
greater heat output. This results in increased heating comfort.

VARIABLE CONTROL

OPERATION

Thermostatically-Controlled Models

WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone

in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.

FOR YOUR SAFETY READ

BEFORE LIGHTING

OPERATING HEATER

6.

With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the burner.
If needed, keep pressing ignitor button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service

person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure
.

7.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7 on page

17. If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.

8.

Slightly depress and turn control knob counterclockwise

C-clockwise

to desired heating level. The burner(s) should light.

Set control knob to any heat level between HI and LO.

Advertising