INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you
must also meet required clearances between fireplace opening and
mantel shelf. If you do not meet the clearances listed in Figure 7, you
will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of
fireplace opening, a hood is not required (see Figure 7).

Determining Minimum Mantel Clearance When
Using a Hood

If minimum clearances in Figure 7 are not met, you must have a
hood. When using a hood there are still certain minimum mantel
clearances required. Follow minimum clearances shown in Fig-
ure 8 when using hood.

NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard.
Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini-
mum clearances shown, you must do one of the
following:
• operate the logs only with the flue damper open
• raise the mantel to an acceptable height
• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level, you must maintain the

minimum distance of 14" to combustibles (see Figure 9).

B. If combustible materials are less than 14" to the fireplace, you

must install appliance at least 5" above the combustible floor-
ing (see Figure 10).

INSTALLATION

Mantel Clearances

Floor Clearances

Figure 7 - Minimum Mantel Clearances Without Using Hood

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

12"

8"

(A)

18"

8"

20"

14"

22"

17"

24"

20"

All minimum
distances are
in inches

Log Set
24"/30" Models

18" Model

2

1

/2

"

6"

8"

10"

14"
Min.

Combustible
Material

Noncombustible Material

Hearth

5"
Min.

Combustible
Material

Figure 10 - Minimum Fireplace Clearances Above Combustible
Flooring

Figure 8 - Minimum Mantel Clearances When Using Hood

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Set

18", 24", 30"
Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

Figure 9 - Minimum Fireplace Clearances If Installed at Floor Level

(GA6050, GA6052,
and GA6053)

All Models