Specifications, Wiring diagrams – Desa 110 User Manual

Page 14

Advertising
background image

14

099176

(Pump Rotor, continued)

10. Install blades, pump plate, air filters,

and filter end cover.

11. Replace fan guard and upper shell.
12. Adjust pump pressure (see page 11).

Note:

If rotor is still binding, proceed as

follows.

13. Perform steps 1 through 6 (see page

13).

14. Place fine grade sandpaper (600 grit)

on flat surface. Sand rotor lightly in
“figure 8” motion four times (see Fig-
ure 30).

15. Reinstall insert and rotor.
16. Perform steps 10 through 12 above.

Blade

Rotor

.003"/.004" Gap
Measured With
Feeler Gauge

Gap Adjusting Screw

Sandpaper

Gap Adjusting Screw

Figure 32 - Wiring Diagram, 70/100/110/150,000 BTU/Hr Models

Figure 30 - Sanding Rotor

Figure 29 - Gap Adjusting Screw Locations

SPECIFICATIONS

Output Rating (BTU/Hr.) 35,000 50,000 55,000 70,000 100,000 110,000 150,000
Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity

(U.S. Gal.)

3.0

4.0

5.0

5.0

9.0

9.0

13.5

Fuel Consumption

(Gal. Per Hr.)

.26

.37

.40

.52

.74

.82

1.10

Electric Requirements

120 V/60 Hz (Same All Models)

Amperage (Normal Run) 2.0

2.0

2.0

2.5

4.5

4.5

4.5

Hot Air Output (CFM)

165

165

175

250

480

490

500

White

Black

Blue

Green

Power Plug
120V 60HZ

Photocell

Spark Plug

Ignitor

Flame

Out

Control

B

Reset

Button

R

Red

Motor

Blue

White

White

White

White

Red

Red

Green

Terminal

Board

Red

Relay

Black

White

Black

Blue

Green

Power Plug
120V 60HZ

Photocell

Spark Plug

Ignitor

Flame

Out

Control

B

Reset

Button

R

Red

Blue

White

White

White

White

Red

Red

Green

Terminal

Board

Motor

Figure 31 - Wiring Diagram, 35/50/55,000 BTU/Hr Models

WIRING

DIAGRAMS

Advertising
This manual is related to the following products: