Functionality, Initial operation – REMKO ATR-1 User Manual
Page 3
 
3
Functionality
 
The desired room temperature is set on either the day or night thermo-
stats. 
The thermostats can be set using the 3-stage mode selector. 
Mode - DAY The room temperature is only controlled via the day 
 thermostat. 
 OFF No control function, the temperature function is 
 switched off, the heating function is also off for the 
 warm air heater. 
Mode - TIMER The room temperature is controlled by the 
 pre-programmed times and the set day/night 
 temperatures. 
Initial Operation
 
Position the housing with the temperature sensors in such a way that op-
timum sensor function is guaranteed. 
If the temperature control is mounted on cold, outdoor walls, the cus-
tomer must install an insulation panel between the wall and the thermo-
stat. 
G
The thermostat sensors may not be directly exposed to a particu-
larly cold or hot stream of air. 
Þ ATR-2; Ready for plug in temperature control:
l Connect the plug of the thermostat cord to the thermostat socket of
the warm air heater.
l Connect the power cord to a properly installed socket (~230V/50Hz).
The green control lamp should now light up.
Þ ATR-1; Temperature control without external cabling:
l Have the temperature control connected and put into operation by
authorised personnel in accordance with the wiring diagram (page 7).
l The unit is ready for operation once the timer, the selection switch
and the desired room temperature have been set.
G
To maintain the timer function, the power current supply must be 
not be interrupted.