Plant – REMKO Multi-talent User Manual

Page 15

Advertising
background image

Plant

Designation

Value range

Factory setting

Description

Operating mode /

Operating mode

Standby

Cooling

Automatic 1+2

Summer

Heating

Reduction

Service

Standby

Setting the operating mode / the operating mode for the
system.

• Standby (heating OFF, water heating OFF,
only frost protection).

• Cooling (heating OFF, only water heating, activation of
the cooling machines, regulation of the heating circuits to
T-supply cooling).

• Automatic 1+2 (heating in accordance with the
heating programme 1/2, WW in accordance with WW-
programme).

• Summer (heating OFF, WW in accordance with WW-
programme).

• Heating (regulation to T-room target).

• Reduction (regulation to T-reduction).

• Service (Controller to Max T-WE,
see Specialist

Cascade

The service mode automatically returns to the
previous operating mode after 15 min..

Language

D/GB/F/NL/E/I

English

Setting the language for the controller.

LCD contrast

00-06

04

Setting the display intensity.

LCD brightness

00-30

30

Setting the display lighting brightness.

°C/°F

Celsius

Fahrenheit

Celsius

Setting the temperature unit.

Summary of settings that can be set by the system operator.

Plant

End

01

Operating mode
Language
LCD contrast
LCD brightness

°C/°F

Hot water

End

01

1 x hot water
T-WW 1 target
T-WW 2 target
T-WW 3 target
BoB value

Circ with WW prog

Anti-legionella

USER

Heating circuit 1

End

01

Operating mode

T-room target 1

T-room target 2

T-room target 3

T-reduction

T-absent
T-room cooling

T-external cooling

Heating threshold day
Heating threshold night

heating curve

T-supply const T

T-supply const N

Room impact
Heating curve adaptation
Warm up opt
Max warm up-time
Reduction opt
PC enable

Heating circuit 2

End

01

Operating mode

T-room target 1

T-room target 2

T-room target 3

T-reduction

T-absent
T-room cooling

T-external cooling

Heating threshold day
Heating threshold night

heating curve

T-supply const T

T-supply const N

Room impact
Heating curve adaptation
Warm up opt
Max warm up-time
Reduction opt
PC enable

Level 4 - USER - Description of parameters and settings

See page 15

See page 16

See page 16-19

See page 16-19

15

Advertising