SYMPTOM

Burner fails to light

Burner lights but goes out when auto-
matic control valve button is released

Burn rate is low

POSSIBLE CAUSE

1. Propane supply valve closed on propane

tank(s)

2. Excess-flow check valve closed

3. Blockage in burner nozzle
4. Piezo ignition system not sparking

1. Not enough warm-up time

2. Low gas pressure
3. Thermocouple loose or needs to be replaced
4. Automatic control valve needs to be re-

placed

1. Main burner valve not fully open

2. Plugged gas orifices
3. Low gas pressure
4. Low fuel supply

REMEDY

1. Open propane supply valve slowly

2. Close propane supply valve on propane tank

and reopen slowly

3. Replace burner nozzle
4. Check to assure ignitor electrode gap is

.130". Check wire lead for damage. Replace
piezo ignitor and/or ignitor electrode as nec-
essary

1. Relight, hold automatic control valve but-

ton in 45 seconds

2. Check propane tank(s) for proper gas supply
3. Tighten connection or replace thermocouple
4. Replace automatic control valve

1. Fully open main burner valve by turning

control knob towards HIGH position until
it stops

2. Replace gas orifice
3. Check gas supply; check regulator output
4. Consult propane gas supplier