Mechanical installation, Electrical connections and setup – Datalogic Scanning CBX500 User Manual

Page 6

Advertising
background image

CBX500 INSTALLATION MANUAL

6

MECHANICAL INSTALLATION


CBX500 can be mounted to various wooden or plastic surfaces using the two self-threading screws (3.9 x 45 mm)
and washers provided in the package.

Mounting to other surfaces such as concrete walls or metallic panels requires user-supplied parts (screws, screw
anchors, nuts, etc). A mounting template is included in the package to facilitate hole drilling alignment.

CBX500 can also be mounted to a DIN rail or a Bosch Frame using the following mounting accessories: BA100
(93ACC1821), BA200 (93ACC1822).

The diagram below gives the overall dimensions of the CBX500 and shows the two mounting through-holes.

178

[

7.01]

82.9

[3.26]

80.9

[3.18]

4

[0.16]

4

[

0.1

6]

71

[2.8]

180

[7.1]

193

[7.6]

30

.7

[1

.2

1]

Figure 1 - Overall Dimensions



ELECTRICAL CONNECTIONS AND SETUP


The following figure shows the typical layout.

Figure 2 – System Layout


The dotted line in the figure refers to an optional (temporary) hardware configuration in which a portable PC can
be quickly connected to the CBX500 (and consequently to the reading device auxiliary interface) through the
internal 9-pin connector. This allows monitoring of the data transmitted by the reading device or configuration

Reading Device
Configuration PC

PWR

Scanner

CBX500

Scanner
Auxiliary
Interface

PS, I/O, Main Interface

Mounting
Holes