SERVICE DIAGNOSIS

DCE33

September 2011

Page 22

PROBLEM

POSSIBLE CAUSE

PROBABLE CORRECTION

No ice falling in bin, but machine
operates

Ice may be stuck in the evaporator
and the unit is “frozen up”.

Check water supply - filter may be
restricted

Check inlet water valve - screen
may be restricted, or valve does
not operate.

Hot gas valve may not operate -
check and repair/replace.

Harvest time set too short - timer
needs adjustment.

Too much heat load.

Inlet water valve leaks thru, needs
to be replaced.

No water spray

Water pump does not work,
replace it.

Water leak from reservoir, locate
and repair.

Cube size control will not close

See “Too much heat load” or “not
enough refrigerant”

Control defective - must be
replaced.

No airflow

Fan motor not turning, needs to
be replaced.

Fan blade broken, needs to be
replaced.

Condenser completely blocked
up, needs cleaning.

Not enough refrigerant

Add low side access valve, locate
leak, recover refrigerant, repair,
replace dryer, evacuate and weigh
in the nameplate charge.

Restricted system

Add low side access valve,
recover refrigerant, replace dryer,
evacuate and weigh in the
nameplate charge.

Hot gas valve leaks thru

Add low side access valve,
recover refrigerant, replace hot
gas valve and dryer, evacuate and
weigh in the nameplate charge.

Compressor will not operate or
pumps poorly.

Start relay or capacitor needs to
be replaced.

Add low side access valve,
recover refrigerant, replace
compressor and dryer, evacuate
and weigh in the nameplate
charge.