Dce33 – Scotsman DCE33 User Manual

Page 9

Advertising
background image

TO INSTALL: Plumbing

Built In Pump Model:

1. Place ice machine in front of installed location.
Adjust leg levelers to approximately correct
position.

2. Remove kickplate and control box cover.

3. Route water inlet line from wall through ice
machine to the front.

4. Locate coil of 3/8" ID plastic drain tubing
secured to the back of the cabinet.

5. Route plastic drain tube from back of cabinet to
drain connection point.

Note: Often an air gap is required by local codes
between the ice machine drain tube and the drain
receptacle.

6. If electrical outlet for ice machine is behind the
cabinet, plug in the ice machine now.

7. Push ice machine into installed position.

8. Cut off water inlet line at required length.

9. Flush water line. Place flare nut on inlet water
line and flare the end of the copper tube.

10. Attach flare nut to the male flare on the inlet
water valve.

11. Turn on the water supply, and make sure that
the ice machine is plugged in and the power is on.

12. Pour a couple of quarts of water into the
storage bin, the drain pump should start and pump
water out. Check for leaks.

13. Replace kickplate and control box cover.

14. Level the cabinet as needed.

ALL PLUMBING MUST MEET LOCAL CODES

DCE33

September 2011

Page 9

THE DCE33 WILL FIT IN A SPACE

15

1

4

" WIDE X 33

3

4

" HIGH.

THE DEPTH OF THE CABINET IS 22" TO

THE FRONT EDGE OF THE HANDLE.

Air Gap Device

(Where Required)

Drain

Connection

Water Shut Off

Valve

Water Filter

(Recommended)

Drain Tube From

Back Of Machine

Water Inlet Connection

WATER AND DRAIN

INSTALLATION

Advertising
This manual is related to the following products: