SPECIFICATION

Earth Bond Test
AC Test Currents ...................

6A, 12A, 20A, 25A @ 6V RMS (nominal)
Corresponds to Type A earth continuity tester as
defined in Electricity at Work Regulations 1989.

...............................................

100mA @ 500mV RMS (nominal)
Corresponds to Type B earth continuity tester as
defined in Electricity at Work Regulations 1989.

...............................................

Electronically controlled constant current to ± 20%
accuracy.

Note: the current will only be controlled within an acceptable test load impedance.
Display Range ......................

0>1.999

Accuracy ...............................

± 10% or 1m

whichever is the greater. ± 2 counts.

Note: Impedance of the earth connector will be significant at low impedances.
Resolution ............................

1m

Test Duration .......................

6 seconds nominal

Insulation Test
DC Test Voltage ..................

480V min, 600V max off load

Display Range .....................

10k

to 19.99M

Accuracy .............................

± 3% or 10k

(whichever is the greater) up to 15.00M

Resolution ...........................

10k

Test Duration ......................

6 seconds nominal

Fuse Test
AC Test Current .................

30 mA max, 9V o/c

Display ...............................

LED Indicator

Display Indication ...............

1K

Protection ...........................

Internal Fuse

Supply Voltage
AC Supply ..........................

240V ± 10% @ 50Hz

Note: Some readings and specification figures are related to supply voltage variation

Physical Data
Dimensions ........................

250mm x 200mm x 150mm (approx)

Weight ................................

4 kilo (approx)

Temperature Range ...........

0° to 40°C (operating), -10° to 70°C (Storage)

............................................

Thermal cut-out will operate when internal
components attain 70°C in order to prevent damage

REPLACEMENT PARTS
Earth Lead .........................

207A915

Insulation Probe .................

207A918

FUSES
Plug Fuse ..........................

5A to BS 1362

There are no user serviceable parts within the unit.

Due to a policy of continuous development Seaward Electronic Limited reserves the right to alter equipment specification
and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of
any contract for the equipment unless specifically referred to as an inclusion within such contract.

211A557-B

10

PAC1500xi inner 154-176 7/3/03 4:43 pm Page 6

Advertising