Seaward 220 PrimeTest User Manual
Page 31

Operating Instructions
Primetest 220
24
9.9 Spare Parts.
Fuse 31.75mm x 6.35mm 12.5A 250V Type T Seaward Part No: 27B111
Test Leads (with alligator clips)
Seaward Part No: 44B124
Carry Case
Seaward Part No: 71G082
Appendix 1
PrimeTest 220 Diagnostic Indications
Mains Supply Icons
PE
PN
NE
The mains supply is too high, too low or not present.
Flash
Flash
Off
These icons can also indicate a fault on RLY2.
Flash
On
Flash
Earth Open - Circuit
On
Flash Flash
Neutral Open - Circuit
Err 1
The PrimeTest 220 has failed one of the Earth Relay Pre-
Check tests. Contact your local service agent.
Err 2
The PrimeTest 220 has failed one of the Safety Relay Pre-
Check tests. Contact your local service agent.
Err 3
The PrimeTest 220 has failed an Internal Relay Pre-
Check test. Contact your local service agent.
Err 4
Preload safety test has failed. EUT load too high.
Err 5
The PrimeTest 220 has failed an Internal Relay Pre-
Check test. Contact your local service agent.
PrimeTest 220 REV 1 5/12/05 1:52 pm Page 29