5.

Once the top and bottom pins are secured, unfold the door into
the closed position.

6.

Repeat the process for the opposite door assembly.

7.

To adjust the doors, slide them partially open. Using a screw-
driver, loosen the hold-down screws in the spring clip (see Fig-
ure 34) and pivot plate.

8.

Close both doors until evenly joined at the middle and note the
gap at the outer edges of the face.

9.

Reopen one door at a time and retighten the upper and lower
hold-down screws.

10. Repeat the process until both doors are evenly joined, spaced

and working freely.

CAUTION: The glass panels become very hot

while the appliance is operating. Do not attempt to
adjust or clean the glass doors until the appliance
has fully cooled.

The doors may be removed for replacement or cleaning as follows:

1.

Partially open the door and press up on the upper spring clip with
a screw driver until the outer top pivot pin is free of the clip.

2.

Fully fold the frame assembly and slide the upper edge to-
wards the center of the firebox opening until the guide pins are
free of the frame rail (see Figure 35).

CAUTION: Always operate the appliance with the

doors either fully opened or fully closed. Operating
the appliance with the doors partially open can result
in improper venting of flue products.

INSTALLATION

Continued

Figure 34 - Adjusting Glass Doors

Spring Clip

Hold-Down
Screw

Side Front
Face

Partially
Opened
Door

Figure 35 - Removing Glass Doors

Spring Clip

Depress Spring
Clip to Release
Pivot Pin

Remove
Bottom Pin
From Pivot
Plate While
Sliding Door
Out of the
Upper Track

Pivot Plate

Fold Bi-Fold
Door After
Releasing
Spring Clip and
Slide Door Out
of Upper Track

CLOSE

OPEN

VENT DAMPER MUST BE LOCKED

IN THE FULL OPEN POSITION

TO OPERATE THE APPLIANCE

Figure 36 - Opening Vent Damper

OPENING VENT DAMPER

Vent damper must be locked in the full open position before
operating the fireplace. If vent damper is not open, fireplace will
not light.

INSTALLATION

Installing Optional Glass Door Accessory (Cont.)
Opening Vent Damper