Pre-installation preparation, Continued, Mantel clearances and wall details – Desa M36E(B User Manual

Page 7

Advertising
background image

108796-01E

7

7

For more information, visit www.desatech.com

For more information, visit www.desatech.com

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12" (229 mm)
from the wall. Figures 5 and 6 show the minimum allowable distances
from various combustible mantle components in relation to the fire-
place opening.

Spacer

3" (76mm)

1

1

/

2

"

(38mm) Max.

B

6" (152mm)

A

12"

(229mm)

Combustible
Materials

Header

Figure 5 - Mantel Clearances - Side View (Cross Section)

1

1

/

2

" (38mm)

Max.

3" (76mm)
Max.

6" (152mm)
Max.

A

B

Outer Surround

Combustible
Material May
Be Used

TOP VIEW

SAFE
ZONE

Perpendicular
Wall

Figure 6 - Side Clearances - Top View (Cross Section)

M36E(B,H)

M42E(B,H)

VM36E(B,H)

VM42E(B,H)

A

9" (229mm)

6" (152mm)

B

12" (305mm)

9" (229mm)

PRE-INSTALLATION PREPARATION

Mantel Clearances and Wall Details

PRE-INSTALLATION
PREPARATION

Continued

M36E(B,H)

M42E(B,H)

VM36E(B,H)

VM42E(B,H)

A

14" (356mm)

15" (381mm)

B

8" (203mm)

9" (229mm)