Status tabs – Sierra Video MFC-8300 User Manual

Page 38

Advertising
background image

6-2

DashBoard Menus

MFC-8300 Series User Manual (Ver. 1.0)

Status Tabs

Table 8.1 summarizes the Status tab parameters available in DashBoard for the MFC-8300 Series
Controller Cards. The Status tabs provide read-only information such as software revision issue, fan
door status, and power consumption.

Table 6.1 Status Tab Items

Tab Title

Item

Parameters

Description

Product

(Read-only)

Frame Name

Name as defined by the user in the Network
tab. Refer to Table 6.4.

Frame S/N

a

Indicates the Frame Serial Number.

Product

Indicates the model number of the card

Supplier

Sierra Video

Board Rev

##

Indicates the hardware revision

Board S/N

######-###

Indicates the card serial number

MAC Address

##-##-##-##-##-##

MAC Address for the card

Software Rev

#.##

Indicates the card software version

Network

(Read-only)

Network Source

DHCP - set by user

SW3-1 and SW3-2 are set to OFF; the
Addressing Mode is set to DHCP in
DashBoard. The network automatically
assigns the card ethernet settings.

Static - set by user

SW3-1 and SW3-2 are set to OFF; the
Addressing Mode is set to Static in
DashBoard. User defines the ethernet
settings from the Network tab.

DHCP - set by DIP

SW3-1 is set to OFF and SW3-2 is set to
ON. The network automatically assigns the
card ethernet settings.

This is not applicable to the MFC-8320-S.

Factory Default 1

SW3-1 is set to ON and SW3-2 is set to
OFF. The IP Address of the card is set to
192.168.2.1. This is not applicable to the
MFC-8320-S.

a

When installed in a DFR-832x series frame only.