Page 45

GENERIC PROTOCOL
39
“N”: Input Status Inquiry
The command "N" requests that matrix status information for a single input be returned to the
host. This command is only useful on those router levels that allow an input to be connected to at
most one output. The status information is sent as a “Y” command or a sequence of L “X”
commands, where L=number of levels that allow an input to be connected to at most one output
(each such level generates a single “X” command of status). Thus, a 6-level router with three
single-output-per input levels would generate 3 “X” commands of status command output. A
router that has all of its levels as single-output-per-input may return a single “Y” command instead
of individual “X” commands if all of the levels are connected to the same output. The “X” and “Y”
commands are formatted exactly as with the "O" command.
For example, the command:
**N4!!
to a router might have the following three commands as its response:
** X12,4,2 X-,4,3 X0,4,4 !!
giving the status of levels 2, 3, and 4 (level 1 presumably not being a single-output-per-input
level). Note that on level 3 the ë-ë (dash) indicates that the input is disconnected, and on level 4
the 0 indicates that the connection to the input is either unknown or that input does not exist or is
not available on that level.
If the router has only one level, or if all levels are connected the same, it might instead use the Y
command. For example:
** Y12,4 !!
“S”: Status Inquiry
Use command S to request that status information be returned to the host. The status information
is sent as a string of L x O substrings, where L = number of levels and O = number of outputs.
Each level/output combination generates a single substring of status. Thus, a 21-level 16 output
router would generate 2x16 = 32 substrings of status command output. The length of each
substring depends on the size of the particular switcher involved. Larger switchers use bigger
numbers for inputs, outputs, and levels.
The first substring of status is for level 1 output 2, etc.; however, each substring contains the level
and output numbers, so the sequence in which the data is sent is not important). The first
characters of each substring are a space followed by “X”, then the output number, a comma
character, the input number connected to the output (or 0 if no connection exists), another
comma, and finally the level number at which the input-output pair is connected. For example, the
command:
**S!!
might have the following two substrings at the beginning of its response:
**x01, 12, 1 x02, 02, 1!!
- Pro XL Series 12 Shasta HD 88 HD Shasta HD 88 SDI 1601 Series HD/SDI Shasta HD Scanning Routing Switchers 1602 Series HD/SDI Shasta HD Routing Switchers 1602 Series HD/SDI Shasta HD Scanning Routing Switchers 1601 Series HD/SDI Dual Output Shasta HD Routing Switchers 1616 Series HD/SDI 3G Shasta HD Routing Switcher Alta Pro Series Tahoe 3232CAA Tahoe 32128V Lassen XL Series VS Lassen XL Series DE Lassen XL Series HD Lassen XL Series SDI Tahoe 3264VAA Tahoe Series 48 Tahoe Series 16 Tahoe Series 20 Shasta 88D Shasta 88E Shasta 1601D Shasta 1616D Tahoe Series 32 Shasta Series 16 Shasta Series 32 Pro XL Series 16 Pro XL Series 32 NLE Pro Series 8 Pro Series 12 Pro Series 16