Skutt EnviroVent User Manual

Page 11

Advertising
background image

11

V

TROUBLESHOOTING

Problem

Cause

Solution

1. Smell or odor
coming from kiln

EnviroVent

leaking between

blower and outside ducting


too many holes and leaks in
upper part of kiln

fumes discharged outdoors are
coming back into room


kiln not venting

seal all leaks around duct connections or

seams and blower box with silicone
sealant or duct tape


plug or repair all cracks in kiln and plug

smallest lid hole-test fire


locate make-up air source further from

discharge exit or raise or extend exit
vent or open ventilation port cover wider


see Section 2

2 Kiln not venting

shelf placed directly on kiln
floor without posts

lid holes drilled above kiln walls

floor holes not within 4 1/2”
plenum opening

kiln moved so floor holes
blocked below by plenum
assembly

exit ducting blocked, kinked or
pinched

flapper on dryer vent not
opening

exit ducting has too many bends
or is too long

support first shelf with posts at least 1”

tall to permit circulation


drill correct holes above firing chamber

drill correct holes above plenum

entrance, plug incorrect holes


move kiln floor or assembly so holes are

aligned



open, straighten or repair exit ducting


replace flapper with easier operating one


reduce the number of bends and the duct

length-avoid 90

bends

3 Kiln slow to reach
temperature

too many holes or air leaks


heating elements have aged or
other factors are affecting kiln
not related to EnviroVent


plug or repair cracks in the kiln, plug

smallest hole, lid and floor, test fire


check heating elements and if necessary

have kiln repair person check kiln