Install vacuum breaker flush connection, Install flushometer, Install flushometer (continued) – Sloan 136 GEM 2 Exposed Flushometer User Manual

Page 4: Flush out supply line

Advertising
background image

4

3

Install Vacuum Breaker Flush

Connection

A

Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud

Flange over Vacuum Breaker Tube.

B

Insert Tube into Fixture Spud.

C

Hand tighten Spud Coupling onto Fixture Spud.

4A

Install Flushometer

4B

Install Flushometer (Continued)

C

Align Flushometer Body and securely tighten first the Tailpiece

Coupling (1), then the Vacuum Breaker Coupling (2), and finally the

Spud Coupling (3). Use a wrench to tighten these couplings in the

order shown.

B

Align Flushometer directly above the

Vacuum Breaker Flush Connection by

sliding the Flushometer Body IN or OUT as

needed. Tighten Vacuum Breaker Coupling

by hand.

A

Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece

into Control Stop. Tighten Tailpiece Coupling by hand.

Maximum adjustment of the Sloan Adjustable Tailpiece is

1/2” (13 mm) IN or OUT from the standard 4-3/4” (121 mm)

(centerline of Flushometer to centerline of Control Stop).

If roughing-in measurement exceeds 5-1/4” (133 mm),

consult factory for longer tailpiece.

NOTE

5

Flush Out Supply Line

A

Make sure Control Stop

is CLOSED and remove

Flushometer Cover.

C

Install Flushometer Cover wrench

tight. Open Control Stop to flush

supply line. Close Control Stop

and remove Flushometer Cover.

B

Lift out Piston Assembly.

D

Reinstall Piston Assembly and

Flushometer Cover. Tighten

Flushometer Cover wrench tight.

VACUUM

BREAKER

TUBE

SPUD COUPLING

NYLON SLIP

GASKET

RUBBER

GASKET

SPUD FLANGE

VACUUM

BREAKER

TUBE

SPUD COUPLING

NYLON SLIP

GASKET
RUBBER

GASKET

SPUD FLANGE

SPUD COUPLING

NYLON

SLIP

GASKET

RUBBER

GASKET

SPUD FLANGE

MODELS 110/111,

115, 136

MODELS 120,

121, 122, 137

MODEL 180

MODEL 186

ELBOW FLUSH

CONNECTION

VACUUM

BREAKER

On valves furnished less vacuum breaker (XYV Variation) connect flush

tube to the bottom of the valve using the slip gasket supplied.

NOTE

D

If not installed, install Handle Assembly with Gasket to handle

opening on Flushometer Body. Tighten Handle Assembly securely.

VACUUM

BREAKER

COUPLING

2

ADJUSTABLE TAILPIECE

O-RING

SPUD

COUPLING

3

C/L

FIXTURE

C/L

SUPPLY

TAILPIECE COUPLING

1

FLUSHOMETER

BODY

4-3/4”

(121 mm)

±1/2”

(13 mm)

G-44 FRICTION

RING

VACUUM

BREAKER

FLUSH

CONNECTION

CONTROL

STOP

HANDLE

ASSEMBLY

GASKET

VACUUM

BREAKER

REPAIR

KIT

For high efficiency urinal flushometers (0.5, 0.25 and 0.125

gpf), it is necessary to first insert the flow control component

into the tailpiece assembly. See the H1015A flow control kit

and separate instructions for details on how to install.

NOTE

Advertising