2-1/4" (57 mm) MIN.

34-3/8"

(873 mm)

9-1/2"

(241 mm)

13-3/4"

(349 mm)

4-3/4" (121 mm)

1-1/2"

(38 mm)

1" I.P.S.

SUPPLY

(25mm DN)

FIN. WALL

FIN. FLOOR

CENTER LINE OF

FIXTURE

TOP OF
FIXTURE

2-1/4" (57 mm) MIN.

34-3/8"

(873 mm)

9-1/2"

(241 mm)

FIN. WALL

FIN. FLOOR

TOP OF
FIXTURE

1-1/2"
(38 mm)

13-3/4"
(349 mm)

24" (610 mm)
"A" DIM 8-5/8" (219 mm) ‡

11-1/2" (292 mm)
"A" DIM 21-1/8" (537 mm) ‡

9" (229 mm)
"A" DIM 23-5/8"
(600 mm) ‡

4-3/4" (121mm)

CENTER LINE
OF FIXTURE

1" I.P.S. SUPPLY
(25 mm DN)

FIN. WALL

FIN. FLOOR

34-3/8"
(873 mm)

2-1/4" (57 mm) MIN.

9-1/2"
(241 mm)

12-5/8"
(321 mm)

2"
(51 mm)

1-1/2"
(38 mm)

CENTER LINE
OF FIXTURE

6-5/8"
(168 mm)

1" I.P.S. SUPPLY
(25 mm DN)

TOP OF
FIXTURE

26-1/2"
(673 mm)

2-1/4" (57 mm) MIN.

9-1/2"
(241 mm)

13-3/4"
(349 mm)

1-1/2" (38 mm)

4-3/4" (121 mm)

CENTER LINE
OF FIXTURE

1" I.P.S. SUPPLY
(25 mm DN)

FIN. WALL

FIN. FLOOR

TOP OF
FIXTURE

26-1/2"
(673mm)

4-1/4"
(108mm)

9-1/2"
(241mm)

18"
(457mm)

10-3/16"
(259mm)

1-1/2"
(38mm)

4-3/4"
(121mm)

1" I.P.S
SUPPLY
(DN 25mm)

1-1/2"
(38mm)

GRAB BAR (NOT
SUPPLIED BY SLOAN)

TOP OF
FIXTURE

FIN. WALL

FIN. FLOOR

CENTER LINE
OF FIXTURE

Royal BPW-1150

STANDARD INSTALLATION

BPW 1000/1005

DV-100/105

FLUSH VOLUME

BPW VALVE CAN BE PROVIDED WITH THE FOLLOWING FLUSHING VOLUMES:

• Standard — Water Saver, 3.5 gpf (13.2 Lpf)
• “-1.6” — Low Consumption, 1.6 gpf (6.0 Lpf)
• “-2.4” — 2.4 gpf (9.0 Lpf) – European Standard

These instructions also for use with Slimline Bedpan Washers with Sloan
Naval, Dolphin, and GEM Flushometers.

RETROFIT INSTALLATIONS

BPW 1010/1015

DV-100/105-R

USE WHEN INSTALLING WITH EXISTING WATER SUPPLY ROUGH-IN

BPW RETROFIT WITH 2" OFFSET

DV-130/135

USED TO REPLACE OLD STYLE AMERICAN STERILIZER AND CHICAGO
FAUCET BEDPAN WASHERS

ADA INSTALLATION

BPW 1100/1105

DV-110/115

USE WHEN VALVE MUST MEET 44" (1118 mm) MAX. HANDLE HEIGHT
REQUIREMENT PER THE AMERICANS WITH DISABILITIES ACT

BPW-1150/1155

DV-120/125

USE WHEN INSTALLATION REQUIRES CLEARANCE AROUND GRAB BARS

DIMENSION “A” IS LENGTH OF PIPE REQUIRED TO RAISE THE SUPPLY TO THE CONTROL

STOP. ELBOW FITTING SUPPLIED.

† IF VALVE IS NOT PROVIDED WITH 13-1/2" (343 mm) V-600-AA VACUUM BREAKER, CUT

VACUUM BREAKER TUBE TO SIZE TO MEET ROUGH-IN HEIGHT.

VALVE ROUGH-IN