2-1/4" (57 mm) MIN.
34-3/8"
(873 mm)
9-1/2"
(241 mm)
13-3/4"
(349 mm)
4-3/4" (121 mm)
1-1/2"
(38 mm)
1" I.P.S.
SUPPLY
(25mm DN)
FIN. WALL
FIN. FLOOR
CENTER LINE OF
FIXTURE
TOP OF
FIXTURE
2-1/4" (57 mm) MIN.
34-3/8"
(873 mm)
9-1/2"
(241 mm)
FIN. WALL
FIN. FLOOR
TOP OF
FIXTURE
1-1/2"
(38 mm)
13-3/4"
(349 mm)
24" (610 mm)
"A" DIM 8-5/8" (219 mm) ‡
11-1/2" (292 mm)
"A" DIM 21-1/8" (537 mm) ‡
9" (229 mm)
"A" DIM 23-5/8"
(600 mm) ‡
4-3/4" (121mm)
CENTER LINE
OF FIXTURE
1" I.P.S. SUPPLY
(25 mm DN)
FIN. WALL
FIN. FLOOR
34-3/8"
(873 mm)
2-1/4" (57 mm) MIN.
9-1/2"
(241 mm)
12-5/8"
(321 mm)
2"
(51 mm)
1-1/2"
(38 mm)
CENTER LINE
OF FIXTURE
6-5/8"
(168 mm)
1" I.P.S. SUPPLY
(25 mm DN)
TOP OF
FIXTURE
26-1/2"
(673 mm)
†
2-1/4" (57 mm) MIN.
9-1/2"
(241 mm)
13-3/4"
(349 mm)
1-1/2" (38 mm)
4-3/4" (121 mm)
CENTER LINE
OF FIXTURE
1" I.P.S. SUPPLY
(25 mm DN)
FIN. WALL
FIN. FLOOR
TOP OF
FIXTURE
26-1/2"
(673mm)
4-1/4"
(108mm)
9-1/2"
(241mm)
18"
(457mm)
10-3/16"
(259mm)
1-1/2"
(38mm)
4-3/4"
(121mm)
1" I.P.S
SUPPLY
(DN 25mm)
1-1/2"
(38mm)
GRAB BAR (NOT
SUPPLIED BY SLOAN)
TOP OF
FIXTURE
FIN. WALL
FIN. FLOOR
CENTER LINE
OF FIXTURE
Royal BPW-1150
STANDARD INSTALLATION
BPW 1000/1005
DV-100/105
FLUSH VOLUME
BPW VALVE CAN BE PROVIDED WITH THE FOLLOWING FLUSHING VOLUMES:
• Standard — Water Saver, 3.5 gpf (13.2 Lpf)
• “-1.6” — Low Consumption, 1.6 gpf (6.0 Lpf)
• “-2.4” — 2.4 gpf (9.0 Lpf) – European Standard
These instructions also for use with Slimline Bedpan Washers with Sloan
Naval, Dolphin, and GEM Flushometers.
RETROFIT INSTALLATIONS
BPW 1010/1015
DV-100/105-R
USE WHEN INSTALLING WITH EXISTING WATER SUPPLY ROUGH-IN
BPW RETROFIT WITH 2" OFFSET
DV-130/135
USED TO REPLACE OLD STYLE AMERICAN STERILIZER AND CHICAGO
FAUCET BEDPAN WASHERS
ADA INSTALLATION
BPW 1100/1105
DV-110/115
USE WHEN VALVE MUST MEET 44" (1118 mm) MAX. HANDLE HEIGHT
REQUIREMENT PER THE AMERICANS WITH DISABILITIES ACT
BPW-1150/1155
DV-120/125
USE WHEN INSTALLATION REQUIRES CLEARANCE AROUND GRAB BARS
‡
DIMENSION “A” IS LENGTH OF PIPE REQUIRED TO RAISE THE SUPPLY TO THE CONTROL
STOP. ELBOW FITTING SUPPLIED.
† IF VALVE IS NOT PROVIDED WITH 13-1/2" (343 mm) V-600-AA VACUUM BREAKER, CUT
VACUUM BREAKER TUBE TO SIZE TO MEET ROUGH-IN HEIGHT.
VALVE ROUGH-IN
- 11xx Slimline Bedpen Washer w/ Royal Flushometer 100 Slimline Bedpen Washer w/ Royal Flushometer 105 Slimline Bedpen Washer w/ Royal Flushometer 110 Slimline Bedpen Washer w/ Royal Flushometer 115 Slimline Bedpen Washer w/ Royal Flushometer 120 Slimline Bedpen Washer w/ Royal Flushometer 125 Slimline Bedpen Washer w/ Royal Flushometer 130 Slimline Bedpen Washer w/ Royal Flushometer 135 Slimline Bedpen Washer w/ Royal Flushometer