Vented type decorative appliance evgl850n, Technical service, Service hints – Desa EVGL850N User Manual

Page 14: Wiring diagram, When gas pressure is too low, When gas quality is bad, Control valve pilot

Advertising
background image

14

107050

VENTED TYPE DECORATIVE APPLIANCE

EVGL850N

®

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.

You can also visit DESA International’s
technical services web site at

www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• fireplace will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

WIRING DIAGRAM

Control
Valve

Pilot

Robertshaw

MODEL SP745 IGNITION CONTROL

STEP DOWN

TRANSFORMER

PV

GND

PV/MV

TR

MV

TH

HEAT
LIMIT

SWITCH

IGN

EV2

SUPPLY

INCOMING
MAIN GAS

EV1

TO

GAS LINE

BURNER

24V AC

120V AC

120V AC

INCOMING

OR BREAKER)

(FUSE BOX

OFF

ON

(SUPPLIED)

WALL SWITCH

GREEN

BLACK

WHITE

120v, 60Hz, 0.7A

ELECTRICAL RATING:

BLACK

WHITE

GREEN

OPTIONAL
REMOTE

CONTROL

Ignitor

Hearth Pan

Connectors
(Not Supplied)

Field Wire

Advertising