Owner’s manual, Mantel clearances and wall details, Framing – Desa EVGL850N User Manual

Page 5: Top view, Outer surround

Advertising
background image

5

107050

OWNER’S MANUAL

MANTEL CLEARANCES AND
WALL DETAILS

A combustible mantel shelf maybe installed a
maximum 9" (229mm) from the wall and
must have a minimum distance of 18" (457mm)
above the fireplace opening. Figures 5 and 6
show the minimum allowable distances from
various combustible mantle components in
relation to the fireplace opening.

Figure 5 - Mantel Clearances - Side View
(Cross Section)

Figure 6 - Side Clearances - Top View
(Cross Section)

FRAMING

1.

Frame appliance enclosure as illus-
trated in Figures 7 and 8.

Note:

If a wall covering is used to line

the enclosure, then all measurements
must be from the surface of the covering.

2.

Place the appliance into the framing and
secure it.

Note:

If appliance is to be raised above

floor level, a platform must be built to
support the appliance.

3.

Install the supply line to the appliance
using a 1/2" NPT black iron gas line ter-
minating 2

5

/

16

" above the bottom of the

appliance. The gas line may be installed
from either side or from the rear of the
appliance (see Figure 15, page 9).

Figure 7 - Rough Opening for Installing in
Wall

Figure 8 - Rough Opening for Corner
Installation

41

7

/

8

"

(1061mm)

15"

(381mm)

36

1

/

4

"

(921mm)

59

1

/

4

"

(1505mm)

29

5

/

8

"

(752mm)

21

3

/

16

"

(538mm)

CORNER INSTALLATION

15

5

/

8

" Min.

(397mm)

36

1

/

4

"

(921mm) Min.

38

1

/

8

"

(968mm) Min.

29.5

°

9"

(229mm)

6"

(152mm)

12"

(305mm)

6" Min.

(152mm)

3" (76mm)

1

1

/

2

"

(38mm) Max.

1

1

/

2

"

(38mm) Max.

3" (76mm) Max.

6" (152mm) Min.

Within 12"

(305mm)

18" (457mm)
Min.

33

°

TOP VIEW

Safe

Zone

Combustible
Materials

Spacer

Header

Combustible
Material May
Be Used

WARNING: When finishing ap-

pliance, Do not overlap combus-
tible material onto the black front
face. Brick, tile, or other noncom-
bustible materials may be applied
to the face provided that any gap
is between the material used and
the face is caulked with a non-
combustible caulking.

4.

Feed flexible gas line through one of three
gas line conduit sleeve and repack insu-
lation to cover any openings. Prepare the
incoming gas line with teflon tape or pipe
joint compound and hook-up incoming
gas line to the flexible gas line.

Note:

If 1/2" NPT black iron pipe does

not mate with fitting at the end of flex-
ible gas line, remove fitting and replace
with a 37 degree flare 3/4"-12, 1/2" NPT
(female) fitting.

Outer Surround