Installation requirements factory mode – SOMFY OREA User Manual

Page 2

Advertising
background image

Installation Requirements

Factory Mode

This mode allows for

end limits

rotation direction modification and setting of the

3

4

Release the buttons after the end-product jogs
briefly UP/DOWN indicating that this transmitter
can operate the motor during programming. The
OREA RTS motor will now operate in a
momentary fashion

Release the STOP button when the end-product
jogs briefly UP/DOWN indicating that the change
has been memorized in the motor. Verify if the
change took place before proceeding.

Press the stop button for
more than 5 seconds

3) Check direction of operation. The DOWN button must correspond to DOWN on the end-product. In the case of an awning,

it will open or extend the awning. If the direction is wrong, change the direction as shown.

CONTROLLING THE OREA RTS MOTOR WHEN SWITCHING POWER ON FOR FIRST TIME

1) The OREA RTS motor must be installed in the tube required for the particular application because the electronic speed

variance detection will not allow the motor to turn if the crown does not rotate. Provide power to the motor. Notice
the motor will not respond to any transmitter until a transmitter is assigned to communicate with the motors receiver.

2) To assign the transmitter to communicate with the motor's receiver, push the UP and DOWN buttons on the

transmitter SIMULTANEOUSLY. The OREA RTS motor records the address of this transmitter, and only this activated
transmitter can be recorded into the memory of the OREA motor. This prevents other transmitters from being recorded
during factory assembly environments.

The motor cable should not act as a direct
conduit for the water to enter the head of
the motor (form drip loops).

ANTENNA

HOOD

If the installation is made up of several RTS motors, only one
RTS motor must be powered during programming.
All other motors must be disconnected. This will avoid interferences
during the initial programming of each motor.
The mounting distance between 2 motor heads should not be less
than 19 inches between RTS motor heads, to avoid possible interference.
Use only SOMFY RTS radio controls.
In order to avoid water penetration, form a "drip loop" with
the power cable and use hood when required.
Use SOMFY accessories (adaptors, brackets, plug ends,...),
rated for the motor torque and total weight of the installation.

NOTE: SOMFY motors conform to IP44
requirements and as such must be
protected against direct weather
elements such as rain, sleet,...etc.

UP

STOP

DOWN

* In case of problems with FACTORY MODE, turn the power off to the motor for 2 sec. and then back on in order to reset it.

(EXAMPLE: If the OREA motor is powered and a different transmitter activates the motor which is not the intended transmitter

to be used for limit setting, then perform a single power cut. This will delete the address currently in memory and allow your
transmitter to be activated.

!

WARNING: For the

to function properly, the transmitter which is memorized into the

motor's receiver, must be configured correctly. The DOWN button MUST correspond to DOWN on the end-product.

In the case of a cassette awning, it will open or extend the awning. If the UP button extends the awning, the wind sensor will
also extend the awning during windy conditions.

Damage and injury could occur. Do not proceed until

proper operation of the transmitter is verified.

EOLIS/SOLIRIS RTS

THIS IS DANGEROUS!

SENSOR