Model 59 operating parameters – Studio Technologies 58 2000 User Manual

Page 24

Advertising
background image

Model 58/59 User Guide

Issue 4, December 2000

Studio Technologies, Inc.

Page 25

for Surround

3. Using the Model 59 Control Console,

select input 1 as the audio source.
Enable monitor output A. Confirm that
inserts 1 and 2, as well as the mute all
and dim functions are disabled. Slowly
turn the rotary level control clockwise.
If audio is heard, stop raising the level
and turn off any active amplifiers. Turn
the level control until it is fully clock-
wise, providing the maximum monitor
output level.

4. Connect the precision audio level

meter to channel 1 of monitor output A.

5. Observing the level meter, adjust

monitor output trim pot 1 to give
exactly +4dBu.

6. Disconnect the level meter and connect

it to channel 2 of monitor output A.

7. Observing the level meter, adjust the

monitor output 2 trim pot to give
exactly +4dBu.

8. Once the monitor outputs on the first

Model 58 have been calibrated, repeat
steps 4-7 for the additional Model 58
units.

9. On the Model 59 Control Console, turn

the output level control to the fully
counterclockwise position.

10. After confirming that the level control

is fully counterclockwise, activate AC
mains power on the audio amplifiers
or amplified speakers.

Model 59 Operating
Parameters

Many StudioComm for Surround functions
can be configured to meet the exact needs
of your installation. Here’s an overview of
what you can configure:

• Input channels active for each of the

inputs

• Monitor output channels active

• Insert operation

• Monitor output mode

• Power-up mute mode

• Channels selected for bypass and

bypass mode

• Reference level

• Dim level

• Remote contact inputs and level control

The Model 59 Configuration Charts,
located at the end of this section, give
details on how each configuration param-
eter is set. An overview of the parameters
is provided in the following paragraphs.

Entering the Configuration Mode

A small button is located on the back of
the Model 59 Control Console, adjacent
to the 9-pin D-sub connector. Pressing
and holding this button for two seconds
places the Model 59 into the configuration
mode. In the configuration mode the
buttons and LEDs no longer perform their
normal function, but instead allow you to
observe and change many of the operat-
ing parameters. The mute/solo mode
LEDs light alternately to indicate that the
configuration mode is active. Once again
pressing and holding the configure button
returns the Model 59 to normal operation.
Note that configuration changes are stored
only after the configuration mode is exited
by pressing and holding the button.

Our apologies to those of you who find the
configure button a pain to use, but it’s
supposed to be that way! Seriously, the
top of the button is slightly recessed from

Advertising