VENTED NATURAL GAS LOGS

LIGHTING

INSTRUCTIONS

OPERATING
APPLIANCE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some gas is
heavier than air and will settle on the
floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

GAS SHUT-OFF

VALVE OPERATION

Flame Adjustment

1.

Adjust the flame ON/OFF by turn-
ing the gas shut-off valve counter-
clockwise

to open or clock-

wise

to close, as necessary.

Shutting Off Appliance

1.

Turn gas shut-off valve clockwise

to the OFF position.

During the 2-3 hour appliance break-in
period, you may detect an odor from the
appliance as the various paints and com-
pounds used in the manufacturing of this
log set cure. This is a normal and tempo-
rary situation that is not cause for alarm.
However, you may want to provide extra
ventilation to the room during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1

hour.

• Burn the logs in consecutive 1 hour pe-

riods raising the flame an additional
2" to full flame height for a total of
three hours.

CURING LOGS

1.

STOP! Read the safety information,
above.

2.

Turn the gas shut-off valve to OFF.

3.

Wait five (5) minutes to clear out any
gas. If you then smell gas STOP! Fol-
low the safety information above. If
you don't smell gas, go on to the next
step.

4.

Light a match and lay it on top of
the pan material about 2" from the
end of the supply side of the pan

5.

Slowly turn the gas shut-off valve ON
until the burner ignites. If the burner
doesn’t ignite within 10 seconds with
the match burning, turn the shut-off
valve OFF and repeat steps 1 through
4 again.

Note:

Operation instructions for GA9150

Remote Ready Valve/Pilot Kit will be
included with the Kit.

1.

STOP! Read the safety information,
column one this page.

2.

Make sure manual shutoff valve is
fully open.

3.

Press in and turn control knob clock-
wise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas around log set
and near floor. If you smell gas,
STOP! See Safety information
, page 2
and Air For Combustion And Ventila-
tion
, pages 4 through 6. If you don’t
smell gas, go to the next step.

5.

Turn control knob counterclockwise

to the PILOT position and

press in. Keep control knob pressed
in for five (5) seconds.

Note:

You may be running this log

set for the first time after hooking up
to gas supply. If so, the control knob
may need to be pressed in for 30 sec-
onds. This will allow air to bleed from
the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the rear of the front burner. If
needed, keep pressing ignitor button
until pilot lights.

Note:

If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

to the ON position. Burner

should light. If burner does not light,
call a qualified service person.

OPERATING

INSTRUCTIONS FOR

GA9050

Ignitor

Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

ON

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

OFF

On

Off

OFF

OFF

Pilot

Thermo-
couple

Figure 21 - Ignitor and Control Knob

Figure 22 - Thermocouple and Pilot

WARNING: Keep flue open

when operating unit.