TROUBLESHOOTING

WARNING: Turn off log set

and let cool before servicing. Only
a qualified service person should
service and repair log set.

POSSIBLE CAUSE

REMEDY

OBSERVED PROBLEM

Continued

Note:

For additional help, visit DESA

International’s Technical Service web
site at

www.desatech.com

.

Note:

All troubleshooting items are listed in

order of operation.

www.desatech.com

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1.

Turn control knob clockwise
to the PILOT position.

2.

Press in and turn control clockwise

to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise

to

the PILOT position.

1. Poor fuel quality

2. Fireplace venting system not drafting

properly

3. Excessive flame impingement or block-

age

4. Improper fuel/air mixture

5. Excessive gas supply/pressure

1. Passage of air/gas across irregular sur-

faces

1. Incorrect gas supply or pressure
2. Blocked burner orifice or burner mani-

fold ports

3. Improper burner orifice size

Log set is smoking/sooting excessively
(

Note:

It is natural and unavoidable for

vented gas log sets to produce moderate
levels of carbon (soot) where flames
contact the logs. This is especially true
with propane/LP gas.)

Burner is excessively noisy
(

Note:

The movement and combustion of

gas will create low, unavoidable levels of
noise.)

Burner flame is too low or too high

1. Contact local natural or propane/LP gas

company

2. Adjust damper wide open and/or have

fireplace and venting professionally
cleaned and checked

3. Separate the logs to allow more flame

passage

4. Remove any foreign items from the

flame pattern and/or check for proper
orifice sizing

5. Preheat flue in very cold weather

1. Relieve any tight bends or kinks in gas

supply line

1. Check for proper gas supply pressure
2. Free burner orifice and manifold ports

of any burrs, paint, or other blockage

3. Verify proper burner orifice sizing (see

Figure 4, page 7)