Two Power Supplies Operation

Make sure the power supplies are NOT energized while making electrical connections to 
the controller. 

a) Connect the constant DC voltage power supply, ≥9 V and <50 V, 150 mA minimum, to the controller (for 

powering the controller electronics): 

 

Positive (+) power supply terminal to JP5‐6 

 

Negative (‐) power supply terminal to JP5‐5 

 

 

 

OR  

Connect  to  JP3  via  the  DC  power  plug,  ≥9  V  and  ≤16  V,  150  mA  minimum  (inside‐positive; 
outside‐negative) 

Do not connect power to JP3 and JP5 at the same time; otherwise the controller and/or 
power supplies might be damaged and a risk of fire might result. 

b) Connect the constant DC voltage power supply, ≥0 V but <50 V, to the controller (for powering the TE 

device): 

 

Positive (+) power supply terminal to JP4‐1 

 

Negative (‐) power supply terminal to JP4‐2 

c)  Do  NOT  connect  the  TE  device  to  the  controller  at  this  time  (unless  you  are  certain  the  set  point  is 

within the allowable range of the TE device). 

d)  See  the  “Controller  Hookup  Diagram  (Two  Power  Supplies  Setup‐Option  1)”  or  “Controller  Hookup 

Diagram (Two Power Supplies Setup‐Option 2)” for further details. 

 

1.4.3

Linear Control Operation

Make sure the power supplies are NOT energized while making electrical connections to 
the controller. 

a) Connect the constant DC voltage power supply, ≥9 V and <50 V, 150 mA minimum, to the controller (for 

powering the controller electronics): 

 

Positive (+) power supply terminal to JP5‐6 

 

Negative (‐) power supply terminal to JP5‐5 

 

 

 

OR  

Connect to JP3 via the DC power plug, ≥9 V and ≤16 V, (inside‐positive; outside‐negative) 

Do not connect power to JP3 and JP5 at the same time; otherwise the controller and/or 
power supplies might be damaged and a risk of fire might result. 

b)  Connect  the  remote  voltage  control  points  of  the  programmable  power  supply  to  the  controller; 

consult the power supply manual for remote control setup: 

Positive (+) remote control terminal to JP5‐12 
Negative (‐) remote control terminal to JP5‐5 
NOTE: depending on the power supply remote control input requirements, an external voltage 
buffer might be required between the controller and the power supply. 

c) Do NOT connect the TE device to the power supply at this time (unless you are certain the set point is 

within the allowable range of the TE device). 

d) See the “Linear Control Hookup Diagram” for further details. 

 

 

 