Installation – Desa CGEF26B User Manual

Page 6

Advertising
background image

www.desatech.com

120927-54B

6

Note: It is strongly advised that you hire
a qualified professional to undertake this
step in order to prevent personal injury.
Once flue is capped, chimney is no longer
suitable for wood burning.

Note: Do not install this unit into a fireplace
that is prone to dampness; the area of instal-
lation must be dry.

4. Plan the power supply. If an existing

grounded outlet is near fireplace, power
cord can run along front of fireplace. If
cord is not long enough to reach outlet, a
grounded extension cord minimum AWG
No. 14 and rated to a minimum of 1875
watts, may be used. If you plan to cut or drill
a hole in existing fireplace for wiring, it is
best to hire a professional to do this step in
order to prevent personal injury. To reduce
the risk of fire, do not run power cord under
rugs, carpets, etc. Arrange power supply
cord away from high traffic areas where it
may pose a tripping hazard.

WARNING: The solid fuel/gas

fireplace has been converted for

use with an electric insert and

cannot be used for original fuels

unless all original parts have

been replaced and the fireplace

has been reapproved by the au-

thority having jurisdiction.

New Construction or Renovation
1. Select a location at least 3 feet (0.9 m)

away from combustible materials such
as curtains or drapes, furniture, bedding,
paper, etc.

2. Mark desired location on floor and store

unit in a safe, dry and dust free location.

3. Frame in an opening leaving at least 1/4"

(6 mm) around the edge of the unit (see
Framing). Any new wiring must be done in
compliance with local and national codes
and other applicable regulations in order to
reduce the risk of fire, electric shock or other
injuries. Therefore, it strongly recommended
that you hire a professional to complete any
such work.

4. Plan you power supply route. See step 4

of Existing Fireplace Installation.

Framing
Figure 4, shows a typical framing of this heater
using combustible materials. All required
clearances to combustibles must be adhered
to. Header height is measured from the base
of the heater.
Tools and building supplies required for
installation:
• Saw

• Square

• Pliers

• Gloves

• Hammer

• Level

• Phillips screwdriver

• Surround

• Framing materials

• Electric drill/bits

• Tape measure
• Wall-finishing materials
• Caulking material

INSTALLATION

Continued

Figure 4 - Framing Heater for New

Construction/Renovation

Length

Header
Height

Depth

0.75"-
0.50"

Model Depth Length Header

Height

26"

9.75"

27"

26"

32"

10.5"

34"

32"

Note: The height that a
combustible mantel is
fitted above the heater is
dependent on the height
of the front selected. The
minimum height is 1" above
the front.

Advertising
This manual is related to the following products: