Vent-free natural gas log heater, Installation, Continued – Desa CY2718N User Manual

Page 10

Advertising
background image

10

104340

VENT-FREE NATURAL GAS LOG HEATER

INSTALLATION

Continued

INSTALLING DAMPER
CLAMP ACCESSORY FOR
VENTED OPERATION

Note:

When used as a vented heater, appli-

ance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.

If your heater is a manually controlled model,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.

1.

The fireplace does not meet the clear-
ance to combustibles requirements for
vent-free operation.

2.

State or local codes do not permit vent-
free operation.

3.

You prefer vented operation.

If reasons number 1 or 2 above apply to you,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
27). This will insure vented operation (see
Figure 11). The damper clamp will keep
damper open. Installation instructions are
included with clamp accessory.

See chart below for minimum permanent
flue opening you must provide. Attach
damper clamp so the minimum permanent
flue opening will be maintained at all times.

Figure 11 - Attaching Damper Clamp

Damper

Damper
Clamp

Damper
Clamp

Damper

Damper

Masonry Fireplace

Chimney

Minimum Permanent

Height (ft.) Flue Opening (sq. ins.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Manufactured Fireplace