104340

VENT-FREE NATURAL GAS LOG HEATER

OBSERVED PROBLEM

Burner does light after ODS/pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Moisture/condensation noticed on windows

Heater produces a whistling noise when
burner is lit

White powder residue forming within burner
box or on adjacent walls or furniture

REMEDY

1. Clean burner (see Cleaning and Main-

tenance, page 20) or replace burner ori-
fice

2. Contact local natural gas company
3. Replace burner orifice

1. Contact local natural gas company
2. Clean burner (see Cleaning and Main-

tenance, page 20) or replace burner ori-
fice

1. Clean burner (see Cleaning and Main-

tenance, page 20) or replace burner ori-
fice

2. Replace damaged burner
3. Replace gas regulator

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning and
Maintenance
, page 20)

2. Replace gas regulator
3. Problem will stop after a few hours of

operation

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local
natural gas company

3. Observe minimum installation clear-

ances (see pages 7 through 9)

4. Clean burner (see Cleaning and Main-

tenance, page 20) or replace burner ori-
fice

1. Turn heater off when using furniture

polish, wax, carpet cleaners, or similar
products

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low
3. Burner orifice diameter is too small

1. Manifold pressure is too low
2. Burner orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing processes

and logs curing

1. Not enough combustion/ventilation air

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue